Profile Variations - Leaf Safe Guttering - Enclosed Roof Gutter System to keep Gutters Clean, Safe & Leaf Free
Leaf Safe Guttering is a new gutter system designed to eliminate the risk of vermin, leaves and other tree debris from clogging up home gutters thereby creating a significant fire or flood hazard.
Variations of Guttering Profiles
Variations may occur in the width (E) of guttering and the leading rolled edge (F), depending on different brands, styles or roll-forming machines used for manufacture.
Leaf Safe capping is based on using a gutter width of 135mm but can be used on gutter widths between 125mm and 145mm (E). Brackets are riveting front and back to spread or compress the gutter cross section to suit the width of the bracket.
Before deciding on fixing method to be used - show Detail (G) or (H) (J) test bracket in the gutter for fit (G). If hook fits snugly into rolled edge, determine height of bracket and using one of the rivet holes which best suits the rear of gutter ehight, drill gutter and fix bracket using one rivet only.
View Diagram 1
If above test fails use front and rear rivet method as folows:-
- Bend up rolled edge with pliers and drill rivet hole into top approximately 5 mm in from edge.
- Lay bracket flat and rivet to gutter (H)
- Twist and stand up bracket, determine height, and using one of the rivet holes which best suits the rear of gutter height drill gutter and fix bracket using one rivet only - (J)
View Diagram 2

At this stage the gutter may appear to spread and be uneven. This will be corrected when the guttering and brackets are raised and screwed permanently to the fascia.
View Diagram 3